Supply and Installation of an Autoclave - Synopsis - Purchase of a Autoclave capable of holding at least six 28 -30L discard boxes and standard kill runs of 134°C 3 minutes Objectives -To secure value for money for state of the art instrumentation for the UoN.

Status: Awarded
Published Date: 26/02/2020
Closing Date: 14/05/2019
Value: £50,000
Provision of an Autoclave - The Biomedical Research Facility at the University of Southampton is seeking to procure a single fit for purpose Autoclave that can withstand the level of constant daily use and will replace a machine that serves our category 2 laboratories as the current autoclave is no longer economical to maintain.

Status: Awarded
Published Date: 13/02/2020
Closing Date: 13/01/2020
Value: neg.
PHE - 170472 - Autoclave 2 & 3 Refurbishment - PHE requires refurbishment of 2 autoclaves.

Status: Awarded
Published Date: 19/12/2019
Closing Date: 20/11/2019
Value: £15,000
RBGKEW/741 Autoclave - Purchase of an autoclave via the LUPC framework for The supply, delivery, installation and post installation services of general laboratory equipment, Lot Three: Safety. Contract term reflects length of service contract.

Status: Closed
Published Date: 17/12/2019
Closing Date: 06/01/2020
Value: neg.
Purchase of an Autoclave - new autoclave will require delivery and installation by the supplier and will be located in the HSE Buxton laboratory block (autoclave room, L.2.24). The equipment will need to be delivered directly to that room by the supplier on an agreed date for installation. The delivery will require contractor engineering input for installation purposes (to be included in quotation) and will also require HSE's on-site Interserve Facilities Management engineering assistance/oversight to ensure that building services are available and appropriate for the item to be plumbed in to water supply and drainage etc. These utilities should already be available as the old autoclave also required similar connectivity. The autoclave must meet all UK pressure vessel and electrical safety standards and because HSE Buxton must treat hazard group 3 microbiological waste the autoclave must be capable of routinely treating bagged biohazard waste at 131oC for up to 1 hour. The purchased item must be a floor standing autoclave (steam sterilization) system that will be located in a dedicated wash/autoclave room at HSE, Buxton, Derbyshire (SK17 9JN). Space within the autoclave room is limited, requiring the installation of a compact system (see images of system to be replaced, below; this is also where the new system will be located). Steam/odour extraction is already in place above the system and the maximum available footprint for this floor standing system beneath the LEV is likely to be: 1.0 m x 1.25 m. NB. This includes any space required to the side of the autoclave to permit lid opening if a top loading, swing open lid is present. SEE FULL STATEMENT OF SERVICES

Status: Closed
Published Date: 11/12/2019
Closing Date: 02/01/2019
Value: neg.
Purchase on an Autoclave - new autoclave will require delivery and installation by the supplier and will be located in the HSE Buxton laboratory block (autoclave room, L.2.24). The equipment will need to be delivered directly to that room by the supplier on an agreed date for installation. The delivery will require contractor engineering input for installation purposes (to be included in quotation) and will also require HSE's on-site Interserve Facilities Management engineering assistance/oversight to ensure that building services are available and appropriate for the item to be plumbed in to water supply and drainage etc. These utilities should already be available as the old autoclave also required similar connectivity. The autoclave must meet all UK pressure vessel and electrical safety standards and because HSE Buxton must treat hazard group 3 microbiological waste the autoclave must be capable of routinely treating bagged biohazard waste at 131oC for up to 1 hour. The purchased item must be a floor standing autoclave (steam sterilization) system that will be located in a dedicated wash/autoclave room at HSE, Buxton, Derbyshire (SK17 9JN). Space within the autoclave room is limited, requiring the installation of a compact system (see images of system to be replaced, below; this is also where the new system will be located). Steam/odour extraction is already in place above the system and the maximum available footprint for this floor standing system beneath the LEV is likely to be: 1.0 m x 1.25 m. NB. This includes any space required to the side of the autoclave to permit lid opening if a top loading, swing open lid is present. SEE FULL STATEMENT OF SERVICES

Status: Closed
Published Date: 04/12/2019
Closing Date: 13/01/2020
Value: neg.
PHE - 170472 - Autoclave 2 & 3 Refurbishment - PHE requires refurbishment of 2 autoclaves.

Status: Closed
Published Date: 14/11/2019
Closing Date: 19/11/2019
Value: neg.
Autoclaves and Dishwashers - The Manchester institute of Biotechnology is having a new sterilisation facility, including a suite of new Autoclaves and dish washers. The facility will primarily be supporting sterilization and 'media' preparation facility for world class research institute. The existing facility primarily has two steam fed autoclaves and two steam fed dish washers and supporting ancillaries. The project will increase capacity and capability to support a sustainable media facility for a world class Biotechnology institute. The project is expected to deliver 3 new autoclaves and support up to 4 dish washers (two existing dish washers and two newly procured dish washers). A combination of steam/powered systems can be used as part of the solution to provide a robust operational facility for years to come. The project period is expected to run through the first half of 2020 with a temporary facility being located near to the MIB facility (The Masdar Building). The temporary facility will have one of the three autoclaves and two dish washers with supporting steam generators.

Status: Closed
Published Date: 04/11/2019
Closing Date: 29/11/2019
Value: neg.
Expansion of Current High Temperature High Pressure (HTHP) Facility - The University wishes to appoint a Contractor to supply a suite of bespoke high temperature high pressure autoclaves to expand our existing capability.

Status: Awarded
Published Date: 18/09/2019
Closing Date: 18/08/2019
Value: £151,624
Replacement of Autoclave - Purchase of 2 x Autoclaves