145 Results (0 seconds)

Status: Closed
Published Date: 16/12/2015
Closing Date: 13/01/2016
Value: £95,000
BFI Nitrate Holding Vaults (NHV) HVAC Upgrade - The Nitrate Holding Vaults (NHV) at BFI Berkhamsted is a temporary storage facility of Nitrate Cellulose Film which was constructed to a high level of fire and structural integrity due to the highly flammable nature of Nitrate Cellulose Film when stored incorrectly. This building is used as a temporary store for Nitrate Cellulose Film which is being conserved or catalogued after being transported from the BFI’s Master Film Store in Gaydon, Warwickshire where it is stored at -5oC +/- 2oC and 30-40%RH. As this is a temporary storage facility and not a long term archive the environmental conditions required from this building are less stringent at 12oC +/- 16C and 35-55%RH. The building contains 24 individual enclosures (cells), each one is made of reinforced concrete, approximately 150mm thick and it is isolated from its neighbour by 150mm of mineral fibre. The BFI seeks a contractor to undertake this works and the main objects and works of the project are; • Replacement of the AHU which serves the Nitrate Holding Vaults to achieve 12oC (minimum) to 16oC (maximum) and 35%RH (minimum) to 55%RH (maximum) at all times throughout the year without rapid swings in either temperature or relative humidity. • Reinstatement of the drench system to protect the building in event of fire. • Removal from use for Nitrate Cellulose Film the 12 cells which are closest to the main BFI National Archive building. • Introduction of a BEMS system to monitor operation of the AHU and conditions being achieved within the store. • Improvements to the fire separation between the NHV’s and the main building including replacement of main entrance door, fire alarm heads and fire alarm panel for the NHV.

Status: Closed
Published Date: 15/12/2015
Closing Date: 14/01/2016
Value: £50,000
New Installation Air Con Units To CCMC Building - The Constabulary is looking to appoint a single supplier for the supply and installation air con unit. These units must be compatible with the existing units currently fitted. In early 2015 4No. Mitsubishi Electric PUHZ-ZRP250YKA Condensing units and 8No. PCA-RPI125KAQ. Under ceiling systems were installed to providing the cooling for the Data room.

Status: Awarded
Published Date: 02/12/2015
Closing Date: 01/12/2015
Value: £90,000
Modification and installation of control dampers and fumigation dampers - The CL4 facility is one of the most critical areas on site and the HSE carry out audit’s on a regular basis. It is their recommendation that we ensure that the ETP’s and inner corridors have gas tight dampers so fumigation can take place in case of a spill. Secondly suite 2 had work done to improve control on pressures and air supply and it is now intended to upgrade Suite 1 to the same level which was also endorsed by the HSE. Project Objectives To purchase and install the correct fumigation dampers within the ETP’s and inner corridor. Operation and the function of the dampers to be integrated into the current fumigation system. This would include specific 13amp sockets etc. and meet the same standard across site. To modify existing duct work, purchase and install suitable manual CV boxes and upgrade/replace motorised dampers with 110v actuators. The operation of the dampers to be integrated into our current BMS system and to operate and control as per suite 2. All new components fitted must be the same make, type and specification as per suite 2. Commission the pressure system to NIBSC specifications and supply all necessary certification, O&M manuals and up to date drawings.

Status: Closed
Published Date: 19/10/2015
Closing Date: 20/11/2015
Value: £100,000
Gas Boiler and Air Conditioning Maintenance - Gas Boiler and Air Conditioning maintenance for The City University. For full details, please see the ITT at: https://www.delta-esourcing.com/respond/K2F78J47T7 This is an Open Procedure - firms are invited to submit a response to the Invitation to Tender.

Status: Awarded
Published Date: 12/10/2015
Closing Date: 12/11/2015
Value: £15,000
CA3139 - Dental Air Condition Replacment - Replace the R22 and alter the air condition system within the dental department at Queens Hospital Burton. - To access this competition: login to https://suppliers.multiquote.com and view the opportunity CA3139. Not registered on MultiQuote - visit https://suppliers.multiquote.com then register and quote CA3139 as the reason for registration. Any queries please contact MultiQuote on 0151 482 9230.

Status: Closed
Published Date: 30/09/2015
Closing Date: 15/10/2015
Value: £90,000
Air Conditioning Equipment Replacement - The General Medical council is seeking to carry out replacement of some of the air conditioning systems located on the 7th floor in St James's Building

Status: Awarded
Published Date: 24/08/2015
Closing Date: 27/11/2015
Value: £25,000
CA3080 - Wall Mounted Split Air-Conditioning Units - Airedale NHS Foundation Trust seeks expressions of interest for the provision and installation of four small split air conditioning units at Airedale General Hospital. Further information to be provided within the ITT document and site surveys will be required prior to submitting an offer. - To access this competition: login to https://suppliers.multiquote.com and view the opportunity CA3080. Not registered on MultiQuote - visit https://suppliers.multiquote.com then register and quote CA3080 as the reason for registration. Any queries please contact MultiQuote on 0151 482 9230.

Status: Awarded
Published Date: 20/07/2015
Closing Date: 28/07/2015
Value: neg.
Blackpool and The Fylde College - New Air Conditioning Dance Rooms - Blackpool and The Fylde College are requesting quotations for the supply delivery, installation and commissioning of air conditioning units to various dance rooms at our University Centre Full details are provided in the documentation attached

Status: Awarded
Published Date: 09/07/2015
Closing Date: 27/07/2015
Value: £100,000
Replacement Heating, Cooling, Ventilation and Associated Services - Replacement of existing VRF Heating/Cooling systems and installation of heat recovery ventilation system to office accommodation in central Leeds.

Status: Closed
Published Date: 26/06/2015
Closing Date: 05/08/2015
Value: £347,868
Supply of HVAC spares - Supply of HVAC spares